• Arch Orthop Trauma Surg · Jan 2021

    Improving the accuracy of patient positioning for long-leg radiographs using a Taylor Spatial Frame mounted rotation rod.

    • Marc-Daniel Ahrend, Felix Finger, Leonard Grünwald, Gabriel Keller, and Heiko Baumgartner.
    • Department of Traumatology and Reconstructive Surgery, BG Trauma Center Tübingen, Eberhard-Karls University of Tübingen, Schnarrenberg-Str. 95, 72076, Tübingen, Germany. marc@ahrend.de.
    • Arch Orthop Trauma Surg. 2021 Jan 1; 141 (1): 55-61.

    IntroductionLong-leg radiographs are used to plan and supervise the correction of bone deformity in patients treated with the Taylor Spatial Frame (TSF). Often radiographs are performed with malpositioning of the limb leading to wrong alignment measurements. The aim of this retrospective study was to show the usefulness of a simple device which might enhance the reproducibility of limb rotation on long-leg radiographs.Materials And MethodsWe included 20 consecutive patients with TSF treatment and at least three long-leg radiographs (4.9 ± 1.3). Eight out of 20 patients received radiographs with the help of a rotation rod (device with two clamps and a carbon tube). It is placed at the most frontal tab of the reference ring while conducting the radiograph. By this means, limb rotation can be controlled. To show the usefulness of this device, two observers measured the relation of the distances between the middle of the reference ring to the medial and lateral fourth hole on the reference ring (TSF-RR). The standard deviation and range of the TSF-RR of all radiographs for each patient was calculated and compared between patients without and with the rotation rod.ResultsThe standard deviations of TSF-RR in patients without the rotation rod was significantly higher compared to patients with rotation rod (observer 1: p = 0.0228, observer 2: p = 0.0038). Also, the range of the TSF-RR within one patient is significant higher (observer 1: p = 0.0279, observer 2: p = 0.0038) in patients without the rotation rod compared to patients with the rotation rod.ConclusionsThe variability of rotation on radiographs was lower with the rotation rod. Therefore, more reproducible and better comparable radiographs can be conducted. Radiologic exposure might be reduced as repetition of wrongly positioned limbs on radiographs are less frequent.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..