Spine
-
Multicenter Study Comparative Study Clinical Trial Controlled Clinical Trial
The effect of pedicle screw/plate fixation on lumbar/lumbosacral autogenous bone graft fusions in patients with degenerative disc disease.
A prospective, multi-center Investigational Device Exemption Study was carried out in the United States using a pedicle screw and plate system to perform a fusion in patients with degenerative disc disease or spondylolisthesis. The patients' pain function, complications, and fusion status were evaluated and compared with literature controls. ⋯ A statistical analysis showed that patients with degenerative disc disease who underwent fusion without pedicle screw instrumentation were over 24 times more likely to have a pseudarthrosis than comparable patients implanted with a pedicle screw/plate system. Regarding the most important goal in performing a spinal fusion--fusion of the spine--the pedicle screw/plate system used in this study was shown to be a safe and efficacious method of facilitating fusion with autogenous bone graft for this patient population.