Acta anaesthesiologica Scandinavica
-
Acta Anaesthesiol Scand · Apr 2005
Randomized Controlled Trial Comparative Study Clinical TrialEfficacy of sufentanil addition to ropivacaine epidural anaesthesia for Caesarean section.
This prospective double-blind trial evaluated the effect of sufentanil addition to epidural ropivacaine for elective Caesarean section. ⋯ Our results suggest that addition of 20 microg of sufentanil improved the epidural anaesthesia with ropivacaine 0.75% for Caesarean section.
-
Acta Anaesthesiol Scand · Apr 2005
Prevalence of IgE antibodies to morphine. Relation to the high and low incidences of NMBA anaphylaxis in Norway and Sweden, respectively.
Anaphylactic reactions to a neuromuscular blocking agent (NMBA) is more than six times as common in Norway as in Sweden, probably due to differences in preoperative sensitization. The prevalence of IgE-sensitization to morphine (MOR) and suxamethonium (SUX) in comparable populations in Bergen, Norway, and Stockholm, Sweden, was studied and related to possible sensitizing agents. ⋯ IgE-sensitization to SUX, MOR and PHO was detected in Norway but not in Sweden. One possible explanation is the unrestricted use of cough mixtures containing MOR derivatives in Norway.
-
Acta Anaesthesiol Scand · Apr 2005
Case ReportsAmiodarone-induced acute lung toxicity in an ICU setting.
Amiodarone is a highly effective antiarrhythmic drug, albeit notorious for its serious pulmonary toxicity. The incidence of amiodarone-induced pulmonary toxicity (APT) appears to be 1% per year (1). We report a case of very acute APT in a man suffering from postoperative atrial fibrillation.
-
Acta Anaesthesiol Scand · Apr 2005
Case ReportsLateral cervical epidural catheter placement using nerve stimulation for continuous unilateral upper extremity analgesia following a failed continuous peripheral nerve block.
This case report describes the application of electrical stimulation (Tsui test) to confirm placement of a cervical epidural catheter for postoperative pain management in a patient with a failed brachial plexus block who underwent upper extremity surgery. An epidural catheter was easily advanced under nerve stimulation guidance to the surgical dermatome C4 level without any resistance from the C7-T1 level. ⋯ This case reminds the clinician that cervical epidural analgesia may serve as an alternative to a difficult continuous peripheral nerve block. Electrical stimulation may also help to confirm cervical epidural catheter placement at the appropriate dermatome to provide effective analgesia with minimal side-effects.
-
Acta Anaesthesiol Scand · Apr 2005
Randomized Controlled Trial Clinical TrialEffect of additives in lidocaine spray on postoperative sore throat, hoarseness and dysphagia after total intravenous anaesthesia.
Laryngo-tracheal lidocaine spray before intubation is associated with an increased risk of postoperative throat problems. Our study investigated the effect of additives contained in lidocaine spray on postoperative sore throat, hoarseness and dysphagia. ⋯ These results suggest that additives in lidocaine spray, not lidocaine itself, contribute to the increase in postoperative throat problems. Therefore, lidocaine spray should be avoided to prevent these unnecessary complications. Our findings also confirm that laryngo-tracheal lidocaine application does not prevent sore throat, hoarseness or dysphagia after total intravenous anaesthesia.