Cerebral vasodilatory capacity assessment for risk stratification in patients with extracranial arterial stenosis or occlusion may be useful. We describe a new method that assesses cerebral vasodilatory capacity as part of catheter-based cerebral angiography. ⋯ Selective vasodilatory response to intra-arterial nicardipine in the affected arterial distribution during catheter-based cerebral angiography may provide new data for risk stratification.
-
The advent of high and ultra-high-field MRI has significantly improved the investigation of infratentorial structures by providing high-resolution images. However, none of the publicly available methods for cerebellar image analysis has been optimized for high-resolution images yet. ⋯ SUITer provides accurate segmentations of infratentorial structures across different resolutions and MR fields.
-
The quantification of spinal cord (SC) atrophy by MRI has assumed an important role in assessment of neuroinflammatory/neurodegenerative diseases and traumatic SC injury. Recent technical advances make possible the quantification of gray matter (GM) and white matter tissues in clinical settings. However, the goal of a reliable diagnostic, prognostic or predictive marker is still elusive, in part due to large intersubject variability of SC areas. Here, we investigated the sources of this variability and explored effective strategies to reduce it. ⋯ The present work explored in a large cohort of healthy subjects the source of intersubject variability of SC areas and proposes effective normalization methods for its reduction.
-
Ultrahigh-field 7T promises more than doubling the signal-to-noise ratio (SNR) of 3T for magnetic resonance imaging (MRI), particularly for MRI of magnetic susceptibility effects induced by B0 . Quantitative susceptibility mapping (QSM) is based on deconvolving the induced phase (or field) and would therefore benefit substantially from 7T. The purpose of this work was to compare QSM performance at 7T versus 3T in an intrascanner test-retest experiment with varying echo numbers (5 and 10 echoes). ⋯ Excellent image quality and good reproducibility was observed. 7T allows equivalent image quality of 3T in half of the scan time.
-
We sought to validate ultrasound as a reliable means of assessing vessel stenosis of vertebral artery origins. ⋯ Ultrasound has good sensitivity and excellent specificity for detecting vertebral origin occlusion. Flow velocity can be used to screen for severe stenosis of vertebral artery at origin.