Anaesthesia
-
Randomized Controlled Trial Comparative Study
Comparison of computer integrated patient controlled epidural analgesia vs. conventional patient controlled epidural analgesia for pain relief in labour.
Computer integrated-patient controlled epidural analgesia (CI-PCEA) is a novel drug delivery system. It automatically titrates the background infusion rate based on the individual parturient's need. In this randomised trial, we compared the local anaesthetic consumption by parturients using CI-PCEA with demand only patient controlled epidural analgesia (PCEA) for labour analgesia. ⋯ The time weighted consumption of local anaesthetic was similar in both groups (mean difference 0.7 mg x h(-1), 95% confidence interval [CI: -2.5, 1.1]; p = 0.425). The CI-PCEA group had higher maternal satisfaction scores: mean (SD) 93 (7) vs. 86 (11), p = 0.042. CI-PCEA does not increase the use of local anaesthetic when compared with demand only PCEA but does increase patient satisfaction.
-
Randomized Controlled Trial
Evaluation of a diclofenac transdermal patch for the attenuation of venous cannulation pain: a prospective, randomised, double-blind, placebo-controlled study.
Venous cannulation, although a minor procedure, is often painful. The present study was planned to evaluate the efficacy of a diclofenac transdermal patch placed over the venepuncture site in decreasing the pain of cannulation. Seventy-two adults undergoing elective surgery were included in this randomised, prospective, double-blind, placebo-controlled study. ⋯ Median [interquartile range] pain scores were 3.0 [2.0-4.0] in the Diclofenac-Hand group, 5.0 [4.3-7.8] in the Diclofenac-Buttock group and 6.5 [4.5-7.0] in the Control group, p < 0.05. The numbers needed to treat were six and two in the Diclofenac-Buttock and Diclofenac-Hand groups, respectively. The application of a diclofenac transdermal patch at the cannulation site appears to be effective in decreasing cannulation pain.
-
Randomized Controlled Trial Comparative Study
Haemodynamic and catecholamine stress responses to the Laryngeal Tube-Suction Airway and the Proseal Laryngeal Mask Airway.
Supraglottic airway devices such as the ProSeal Laryngeal Mask Airway (PLMA) and Laryngeal Tube-Suction Airway (LTS) that provoke the least stress responses could be beneficial in many situations, especially in patients with cardiovascular disease. We compared the haemodynamic and catecholamine stress response of the LTS and PLMA in a randomised study of 36 patients. Mean arterial pressure, heart rate, epinephrine and norepinephrine levels were all reduced following induction of anaesthesia with no significant differences between the two groups. ⋯ However, following the insertion of the PLMA, mean arterial pressure, heart rate, epinephrine and norepinephrine levels remained significantly lower than pre-induction values. Mean arterial pressure, heart rate and epinephrine were significantly greater in the LTS group than in the PLMA group. We conclude that the LTS produces a greater and more sustained haemodynamic and catecholamine stress response than does the PLMA.