Anaesthesia
-
Comparative Study
The TEG vs the ROTEM thromboelastography/thromboelastometry systems.
We have evaluated the TEG thromboelastograph and the ROTEM thromboelastometer, two point-of-care devices that measure blood coagulation. During a one-week period, seven consultant anaesthetists, one consultant haematologist, one associate specialist anaesthetist and two senior trainee anaesthetists were trained by the manufacturers and set up, calibrated and used both systems, after which their views were obtained and specific technical/support information was sought from the manufacturers using a questionnaire. Although the devices shared common features, they differed in complexity and aspects of ease of use, and in their purchase and running costs.
-
Randomized Controlled Trial Multicenter Study
Ondansetron has similar clinical efficacy against both nausea and vomiting.
Ondansetron is widely believed to prevent postoperative vomiting more effectively than nausea. We analysed data from 5161 patients undergoing general anaesthesia who were randomly stratified to receive a combination of six interventions, one of which was 4 mg ondansetron vs placebo. For the purpose of this study a 20% difference in the relative risks for the two outcomes was considered clinically relevant. ⋯ Vomiting was reduced from 17% (441/2585) to 11% (293/2576), corresponding to a relative risk of 0.67, or a relative risk reduction of 33%. The relative risks of 0.67 and 0.74 were clinically similar and the difference between them did not reach statistical significance. We thus conclude that ondansetron prevents postoperative nausea and postoperative vomiting equally well.
-
Review
B type natriuretic peptide--a diagnostic breakthrough in peri-operative cardiac risk assessment?
The B-type natriuretic peptides; B-type natriuretic peptide and N-terminal pro-B-type natriuretic peptide, are increasing being used as biomarkers for the diagnosis, management and prognostication of cardiac failure, but their application in the peri-operative period is unclear. This review examines the current understanding of the role of B-type natriuretic peptides in both the operative and non-operative settings. ⋯ Using this as a background, the role of B-type natriuretic peptides in the prediction of peri-operative mortality and morbidity is examined and potential confounders, such as renal failure and body mass index, which may impact significantly on the utility of the biomarkers, are discussed. Clinical recommendations with regard to its use are made and a research agenda is proposed for future peri-operative studies.
-
Randomized Controlled Trial Comparative Study
Tramadol for prevention of postanaesthetic shivering: a randomised double-blind comparison with pethidine.
The present study was conducted with the aims of comparing intravenous tramadol 1, 2 and 3 mg.kg(-1) with pethidine 0.5 mg.kg(-1) for prophylaxis of postanaesthetic shivering and to find a dose of tramadol that could provide the dual advantage of antishivering and analgesic effect in the postoperative period. The study included 165 patients, randomly allocated to five groups of 33 each. ⋯ All three doses of tramadol were effective and comparable to pethidine in preventing postanaesthetic shivering. Tramadol 2 mg.kg(-1) had the best combination of antishivering and analgesic efficacy without excessive sedation and thus appeared to be a good choice to be administered at the time of wound closure to provide antishivering effect and analgesia without significant side effects in the postoperative period.
-
Randomized Controlled Trial Comparative Study
Ease of intubation with the GlideScope or Airway Scope by novice operators in simulated easy and difficult airways--a manikin study.
The GlideScope and Airway Scope are video laryngoscopes that have been found to be useful in difficult airway situations. With the GlideScope, there are frequently problems associated with insertion of the tracheal tube despite the ability to view the glottis. The Airway Scope's imaging system and disposable PBlade aid alignment of the PBlade with the glottis and guide insertion of the tracheal tube. ⋯ We found that the students required less time for tracheal intubation with the Airway Scope and reported greater ease of intubation with the Airway Scope in both scenarios. A greater number of students chose the Airway Scope as their device of choice. Our results suggest that the Airway Scope's features may improve the ease of tracheal intubation compared with the GlideScope.