Anaesthesia
-
Randomized Controlled Trial
The effect of short time periods of pre-operative warming in the prevention of peri-operative hypothermia.
The aim of our study was to evaluate the performance of different durations of active pre-operative skin-surface warming (pre-warming) to prevent peri-operative hypothermia and postoperative shivering. We randomly assigned 200 patients, scheduled for surgery of 30-90 min under general anaesthesia, to receive passive insulation or forced-air skin surface warming for 10, 20 or 30 min. Body temperature was measured at the tympanic membrane. ⋯ Without pre-warming, 38/55 (69%) patients became hypothermic (< 36 °C) at the end of anaesthesia, whereas only 7/52 (13%), 3/43 (7%) and 3/50 (6%) patients following 10, 20 or 30 min pre-warming, respectively, became hypothermic (p < 0.001 vs no pre-warming). Shivering was observed in 10 patients without, and in three, three and one patients with pre-warming in the respective groups (p = 0.02). Pre-warming of patients for only 10 or 20 min before general anaesthesia mostly prevents hypothermia and reduces shivering.
-
Guideline
Checking anaesthetic equipment 2012: association of anaesthetists of Great Britain and Ireland.
A pre-use check to ensure the correct functioning of anaesthetic equipment is essential to patient safety. The anaesthetist has a primary responsibility to understand the function of the anaesthetic equipment and to check it before use. Anaesthetists must not use equipment unless they have been trained to use it and are competent to do so. ⋯ A two-bag test should be performed after the breathing system, vaporisers and ventilator have been checked individually. A record should be kept with the anaesthetic machine that these checks have been done. The 'first user' check after servicing is especially important and must be recorded.
-
Randomized Controlled Trial
Combined spinal epidural vs epidural labour analgesia: does initial intrathecal analgesia reduce the subsequent minimum local analgesic concentration of epidural bupivacaine?
Labour analgesia initiated using a combined spinal-epidural (CSE) technique may reduce subsequent epidural bupivacaine requirements compared with an epidural-only technique. We compared the minimum local analgesic concentrations (MLAC) of epidural bupivacaine following initial intrathecal or epidural injection. In a prospective, double-blind study, 115 women requesting epidural analgesia were randomly assigned to receive either an epidural with bupivacaine 20 mg and fentanyl 40 μg or a CSE with intrathecal bupivacaine 2.5 mg and fentanyl 5 μg. ⋯ When further analgesia was requested, bupivacaine 20 ml was given, and the concentration was determined using the technique of up-down sequential allocation. The MLAC of bupivacaine in the epidural group was 0.032% wt/vol (95% CI 0.020-0.044) compared with 0.047% wt/vol (95% CI 0.042-0.052) in the CSE group. Bupivacaine requirements for the second injection were increased following intrathecal analgesia by a factor of 1.45 (p = 0.026) compared with epidural analgesia.