Anaesthesia
-
Randomized Controlled Trial
Supplementation of standard pre-oxygenation with nasal prong oxygen or machine oxygen flush during a simulated leak scenario.
The presence of a facemask leak significantly reduces the effectiveness of pre-oxygenation and increases the risk of post-induction hypoxia. We randomly assigned 24 healthy volunteers to a six-period crossover trial with and without a simulated facemask leak. Pre-oxygenation was performed using a standard anaesthesia machine circuit supplemented either by nasal prong oxygen or by anaesthesia machine flush oxygen. ⋯ With a simulated facemask leak introduced, the mean (SD) end-tidal oxygen fraction with the 3-min tidal breath technique was 74.7 (9.3)% compared with 57.5 (6.2%) for the 8 deep breath technique with 3-min tidal breathing and a leak. End-tidal oxygen fractions increased by 11.0% (95% CI 7.8-14.3%) (p < 0.0001) with the addition of nasal prong oxygenation and 16.8% (13.6-20.0%) (p < 0.0001) with machine oxygen flush compared with standard pre-oxygenation. When a leak is present, 3-min tidal breathing with either nasal prong or anaesthesia machine flush oxygenation is an effective pre-oxygenation method, and preferable to the 8 deep breath method.