The Tulip airway is an adult, disposable, single-sized oropharyngeal airway, that is connectable to an anaesthetic circuit. After a standardised induction of anaesthesia in 75 patients, the ease of insertion, intracuff pressure and intracuff volume were measured, as were the end-tidal carbon dioxide levels, airway pressures and tidal volumes over three breaths. Successful first-time insertion was achieved in 72 patients (96%, CI 88.8-99.2%) and after two attempts in 74 patients (99%, CI 92.8-100%). ⋯ In 60 patients (80%, CI 72.2-90.4%), the Tulip airway provided a patent airway without additional manoeuvres, but in 14 patients, jaw thrust or head extension was necessary for airway patency. The main need for these adjuncts appeared to be an initial under-inflation of the cuff. These promising results are consistent with recent manikin studies using this device.
-
A single-use flexible bronchoscope with a large suction channel has become available recently and we have evaluated this innovative device. Firstly, bronchoalveolar lavage was performed and quantified in ventilated piglets. Next, the bronchoscope was evaluated in three intensive care units and a satisfaction questionnaire was carried out. ⋯ Quality and performance of all devices tested was identical. The medical satisfaction questionnaire was as follows: 'acceptable' to 'very good' for quality of aspiration, manoeuvrability and quality of vision; 'very good' to 'perfect' for setting up and insertion. This encouraging preliminary evaluation demonstrates the effectiveness of this new single-use device, which may obviate the need for disinfection procedures and, thereby, eradicate a potential vector of patient cross-contamination.
-
We evaluated whether pulse pressure variation can predict fluid responsiveness in spontaneously breathing patients. Fifty-nine elective thoracic surgical patients were studied before induction of general anaesthesia. After volume expansion with hydroxyethyl starch 6 ml.kg(-1) , patients were defined as responders by a ≥ 15% increase in the cardiac index. ⋯ Median (IQR [range]) pulse pressure variation during forced inspiratory breathing was significantly higher in responders (n = 29) than in non-responders (n = 30) before volume expansion (18.2 (IQR 14.7-18.2 [9.3-31.3])% vs. 10.1 (IQR 8.3-12.6 [4.8-21.1])%, respectively, p < 0.001). The receiver-operating characteristic curve revealed that pulse pressure variation during forced inspiratory breathing could predict fluid responsiveness (area under the curve 0.910, p < 0.0001). Pulse pressure variation measured during forced inspiratory breathing can be used to guide fluid management in spontaneously breathing patients.
-
Incident reporting is promoted as a key tool for improving patient safety in healthcare. We analysed 2238 patient safety incidents involving medications submitted from up to 29 critical care units each year in the North West of England between 2009 and 2012; 452 (20%) of these incidents led to harm to patients. Although 1461 (65%) incidents were judged to have been preventable, there was no reduction in the rate of incidents per 1000 days between 2009 and 2012 (5.9 in 2009, 6.6 in 2012). ⋯ The most commonly reported drugs were noradrenaline (161 incidents, 92 with harm), heparins (153 incidents, 29 with harm), morphine (131 incidents, 14 with harm) and insulin (111 incidents, 54 with harm). The administration of drugs was the stage in the process where incidents were most commonly reported; it was also the stage most likely to harm patients. We conclude that the wide range in reported rates between units, and the scope for preventing many incidents, suggest that quality improvement initiatives could improve medication safety in the units studied.
-
The objective of this study was to estimate the minimal effective anaesthetic concentrations of ropivacaine required to block the femoral nerve in 90% of patients. Forty-five patients who had knee surgery received ultrasound-guided femoral nerve block using 15 ml ropivacaine. The ropivacaine concentration given to a patient relied on the efficacy of the block in the previous patient, using the biased-coin design up-down sequential method. ⋯ Successful block was defined as complete sensory and motor block before surgery together with pain-free surgery. The minimal effective ropivacaine concentration was estimated to be 0.167% w/v (95% CI 0.14-0.184%). Perineural injection of 15 ml ropivacaine 0.167% w/v under ultrasound guidance can provide successful femoral nerve block in 90% of patients.