Anaesthesia
-
We included six trials with 2524 participants. Capnography reduced hypoxaemic episodes, relative risk (95% CI) 0.71 (0.56-0.91), p = 0.02, but the quality of evidence was poor due to high risks of performance bias and detection bias and substantial statistical heterogeneity. The reduction in hypoxaemic episodes was statistically homogeneous in the subgroup of three trials of 1823 adults sedated for colonoscopy, relative risk (95% CI) 0.59 (0.48-0.73), p < 0.001, although the risks of performance and detection biases were high. There was no evidence that capnography affected other outcomes, including assisted ventilation, relative risk (95% CI) 0.58 (0.26-1.27), p = 0.17.
-
We included six trials with 2524 participants. Capnography reduced hypoxaemic episodes, relative risk (95% CI) 0.71 (0.56-0.91), p = 0.02, but the quality of evidence was poor due to high risks of performance bias and detection bias and substantial statistical heterogeneity. The reduction in hypoxaemic episodes was statistically homogeneous in the subgroup of three trials of 1823 adults sedated for colonoscopy, relative risk (95% CI) 0.59 (0.48-0.73), p < 0.001, although the risks of performance and detection biases were high. There was no evidence that capnography affected other outcomes, including assisted ventilation, relative risk (95% CI) 0.58 (0.26-1.27), p = 0.17.
-
In many orthopaedic operating rooms, anaesthesia providers routinely wear lead aprons for protection from radiation, but some studies have questioned whether this is needed. We conducted a systematic review to identify studies that measured the amount of radiation that anaesthetists were exposed to in the orthopaedic operating room. ⋯ Radiation doses at this distance were often at the limits of the sensitivity of the measuring dosimeter. We question the need to wear lead protection for anaesthesia providers who are routinely at 1.5 m or a greater distance from standard fluoroscopy units.
-
In many orthopaedic operating rooms, anaesthesia providers routinely wear lead aprons for protection from radiation, but some studies have questioned whether this is needed. We conducted a systematic review to identify studies that measured the amount of radiation that anaesthetists were exposed to in the orthopaedic operating room. ⋯ Radiation doses at this distance were often at the limits of the sensitivity of the measuring dosimeter. We question the need to wear lead protection for anaesthesia providers who are routinely at 1.5 m or a greater distance from standard fluoroscopy units.