Anaesthesia
-
The measurement of injection pressure during the performance of peripheral nerve blocks can be pivotal to detect intraneural placement of the needle tip and thus avoid intrafascicular injection. However, injection pressure can only be measured along the injection line (tubing), which is influenced by several factors. The primary aim of this feasibility study was to describe and validate the principle of a novel nerve-block needle conceived for real-time continuous monitoring of injection pressures at the needle tip. ⋯ The mean (95%CI) difference between pressures at the needle tip and the injection line varied substantially from 14.33 (12.58-16.08) kPa at 0.5 ml injected volume to 41.56 (39.66-43.45) kPa at the end of the injection. This study demonstrates that the described system allows for real-time continuous monitoring of injection pressure at the needle tip. Moreover, this study shows that injection pressure values measured in the injection line cannot be assumed to be a reliable indicator of the injection pressure at the needle tip.
-
We have evaluated the effect of a colloid solution on acute kidney injury in paediatric cardiac surgery. A total of 195 patients were ramdomly divided into an hydroxyethyl starch group and a control group. In the starch group, 6% hydroxyethyl starch 130/0.4 (Volulyte® ) was used as the primary fluid for volume resuscitation but was limited to 30 ml.kg-1. ⋯ There was no difference in transfusion between the two groups. Patients with acute kidney injury had worse clinical courses than those without acute kidney injury. We conclude that intra-operative use of 6% hydroxyethyl starch 130/0.4 up to 30 ml.kg-1 was not associated with postoperative acute kidney injury in paediatric cardiac patients.