The British journal of surgery
-
Randomized Controlled Trial Multicenter Study
Survival analysis of the CEAwatch multicentre clustered randomized trial.
The CEAwatch randomized trial showed that follow-up with intensive carcinoembryonic antigen (CEA) monitoring (CEAwatch protocol) was better than care as usual (CAU) for early postoperative detection of colorectal cancer recurrence. The aim of this study was to calculate overall survival (OS) and disease-specific survival (DSS). ⋯ There was no direct survival benefit in favour of the intensive programme, but the CEAwatch protocol led to a higher proportion of recurrences being detected by CEA-based blood test and reduced the number detected by patient self-report. This is important because detection of recurrence by blood test was associated with significantly better survival than patient self-report, indirectly supporting use of the CEAwatch protocol.
-
Randomized Controlled Trial
Randomized clinical trial of landiolol hydrochloride for the prevention of atrial fibrillation and postoperative complications after oesophagectomy for cancer.
Atrial fibrillation is common after oesophageal surgery. The aim of this study was to evaluate whether landiolol hydrochloride was effective and safe in the prevention of atrial fibrillation after oesophagectomy, and to see whether a reduction in incidence of atrial fibrillation would reduce other postoperative complications. ⋯ Landiolol was effective and safe in preventing atrial fibrillation after oesophagectomy. Registration number: UMIN000010648 (http://www.umin.ac.jp/ctr/).
-
Randomized Controlled Trial Multicenter Study
Randomized clinical trial of biodegradeable intraluminal sheath to prevent anastomotic leak after stapled colorectal anastomosis.
Anastomotic leakage is a potential major complication after colorectal surgery. The C-seal was developed to help reduce the clinical leakage rate. It is an intraluminal sheath that is stapled proximal to a colorectal anastomosis, covering it intraluminally and thus preventing intestinal leakage in case of anastomotic dehiscence. The C-seal trial was initiated to evaluate the efficacy of the C-seal in reducing anastomotic leakage in stapled colorectal anastomoses. ⋯ C-seal application in stapled colorectal anastomoses does not reduce anastomotic leakage. Registration number: NTR3080 (http://www.trialregister.nl/trialreg/index.asp).
-
Randomized Controlled Trial
Impact of simulated three-dimensional perception on precision of depth judgements, technical performance and perceived workload in laparoscopy.
This study compared precision of depth judgements, technical performance and workload using two-dimensional (2D) and three-dimensional (3D) laparoscopic displays across different viewing distances. It also compared the accuracy of 3D displays with natural viewing, along with the relationship between stereoacuity and 3D laparoscopic performance. ⋯ 3D displays offer large improvements over 2D displays in precision of depth judgements, technical performance and perceived workload.