    Effect of humidifying devices on the measurement of tidal volume by mechanical ventilators.

    • Yasuki Fujita, Hideaki Imanaka, Yuji Fujino, Muneyuki Takeuchi, Toshiji Tomita, Takashi Mashimo, and Masaji Nishimura.
    • Intensive Care Unit, Osaka University Hospital, 2-15 Yamadaoka, Suita, 565-0871, Japan.
    • J Anesth. 2006 Jan 1;20(3):166-72.

    PurposeWe hypothesized that expiratory tidal volume was underestimated, because a heat-moisture exchanger traps the expired vapor. We, therefore, designed patient and bench studies to investigate the accuracy of tidal volume monitoring.MethodsIn a patient study, applying two humidifying systems (a heat-moisture exchanger and a heated humidifier) and two tidal volumes (12 and 6 ml x kg(-1)) with a Servo ventilator 300, we recorded the displayed expiratory tidal volume and thoracic volume displacement, measured by respiratory inductive plethysmography. Temperature, relative humidity, and absolute humidity were measured at the airway opening and at the end of the expiratory limb. Using a model lung, we also tested three different ventilators (Puritan-Bennett 7200ae, Evita 4, and Servo ventilator 300) to investigate whether the effects of the heat-moisture exchanger and the heated humidifier on monitored tidal volume varied according to the brand of ventilator.ResultsWith the use of the heat-moisture exchanger, the displayed expiratory tidal volume was significantly smaller, by 12%-14%, than that with the heated humidifier, although thoracic volume displacement was identical in the two systems. The temperature and absolute humidity at the end of the expiratory limb were significantly lower with the heat-moisture exchanger than with the heated humidifier. In the model lung study, we investigated the effects of different brands of ventilator on the expiratory tidal volume. A similar degree (8%-14%) of underestimation of tidal volume was observed with the heat-moisture exchanger, regardless of ventilator brand.ConclusionMonitored expiratory tidal volume was underestimated by approximately 10%, when using a heat-moisture exchanger.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

Want more great medical articles?

Keep up to date with a free trial of metajournal, personalized for your practice.
1,624,503 articles already indexed!

We guarantee your privacy. Your email address will not be shared.