• J Neuroimaging · Jan 2020

    Ultrasound Criteria for Assessment of Vertebral Artery Origins.

    • Cory J Rice, Sung-Min Cho, Tamara Strohm, Larry Raber, Irene L Katzan, M Shazam Hussain, and Ken Uchino.
    • Cerebrovascular Center, Neurological Institute, Cleveland Clinic, Cleveland, OH.
    • J Neuroimaging. 2020 Jan 1; 30 (1): 45-49.

    Background And PurposeWe sought to validate ultrasound as a reliable means of assessing vessel stenosis of vertebral artery origins.MethodsWe reviewed 1,135 patient charts with ultrasound of the posterior circulation performed in 2008-2015 in a single hospital. Inclusion criteria for native vessels consisted of ultrasound and digital subtraction angiography (DSA) performed within 3 months. Patients with indwelling stents were analyzed separately from native vessels. Using DSA as the gold standard, we determined sensitivity and specificity of ultrasound in detecting occlusion at vertebral artery origin. All patients with nonoccluded native vertebral artery origins were evaluated for degree of stenosis on DSA, and compared to mean flow velocity (MFV), peak systolic velocity (PSV), and end-diastolic velocity (EDV) on ultrasound.ResultsAmong 218 vertebral artery origins in 139 patients evaluated, ultrasound showed sensitivity of 85.7% (95% confidence interval (CI): 69.7-95.2%) for occlusion and specificity of 99.5% (95%CI: 96.9-99.9%). Among 126 arteries without occlusion, <50% stenosis had average MFV (39 ± 19 cm/s), 50-69% stenosis had average MFV (68 ± 35 cm/s), and severe (70-99%) stenosis had average MFV (120 ± 93 cm/s) (P < .001). MFV cutoff value of 44 cm/s corresponded to 77% sensitivity and 70% specificity to detect vertebral artery origin stenosis >50% (C-statistic: .81). PSV value of 97 cm/s corresponded with 72% sensitivity and 70% specificity to detect >50% stenosis (C-statistic: .77). MFV cutoff value of 60 cm/s corresponded with 70% sensitivity and 82% specificity to predict 70-99% stenosis (C-statistic: .83). PSV cutoff value of 110 cm/s corresponded with 80% sensitivity and 72% specificity to predict 70-99% stenosis (C-statistic: .84).ConclusionUltrasound has good sensitivity and excellent specificity for detecting vertebral origin occlusion. Flow velocity can be used to screen for severe stenosis of vertebral artery at origin.© 2019 by the American Society of Neuroimaging.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

Want more great medical articles?

Keep up to date with a free trial of metajournal, personalized for your practice.
1,624,503 articles already indexed!

We guarantee your privacy. Your email address will not be shared.