Anaesthesia
-
Randomized Controlled Trial Comparative Study
A randomised controlled trial comparing the McGrath(®) videolaryngoscope with the straight blade laryngoscope when used in adult patients with potential difficult airways.
Studies show that both straight blade laryngoscopy and videolaryngoscopy can improve the view of the larynx when compared with the Macintosh blade laryngoscopy. However, no study has compared these two devices. A total of 80 patients with Mallampati grade ≥ 3 were randomly assigned to either have orotracheal intubation with the McGrath(®) videolaryngoscope or the Henderson straight blade. ⋯ There were no statistically significant differences in the secondary outcomes. Two patients suffered from minor oropharyngeal injuries in the Henderson group. Apart from offering significantly more grade-1 laryngoscopic views, the McGrath videolaryngoscope did not improve other clinical outcomes compared with the straight blade, when used in patients with poor Mallampati scores.
-
Randomized Controlled Trial
Ideal versus corrected body weight for dosage of sugammadex in morbidly obese patients.
To date, the dosing of sugammadex is based on real body weight without taking fat content into account. We compared the reversal of profound rocuronium-induced neuromuscular blockade in morbidly obese patients using doses of sugammadex based on four different weight corrections. One hundred morbidly obese patients, scheduled for laparoscopic bariatric surgery under propofol-sufentanil anaesthesia, were randomly assigned four groups: ideal body weight; ideal body weight + 20%; ideal body weight + 40%; and real body weight. ⋯ Secondary endpoints were the ability to get into bed independently on arrival to the post-anaesthetic care unit and clinical signs of residual paralysis. There was no residual paralysis in any patient. Morbidly obese patients can safely be decurarised from rocuronium-induced neuromuscular blockade T1-T2 with sugammadex dosed at 2 mg.kg(-1) ideal body weight + 40% (p < 0.0001).
-
Randomized Controlled Trial
Evaluation of a novel needle guide for ultrasound-guided phantom vessel cannulation.
We evaluated a novel, sled-mounted needle guide for ultrasound-guided vessel cannulation. Fifty medical students were randomly assigned to use ultrasound with the sled (sled group, n = 23) or ultrasound without the sled (control group, n = 27) for vessel cannulation in a phantom. For each of 15 attempts we recorded cannulation time and designated a successful cannulation as 1 and a failure as 0. ⋯ Cannulation time decreased from the first to the last attempt in the sled group from 7.0 s (6.0-10.0 [4.0-16]) s to 4.0 s (3.0-4.0 [1.0-6.0]) s and in the control group from 35.0 s (27.0-35.0 [11.0-35.0]) s to 7.0 s (5.0-10.0 [3.0-25.0]) s. The sled group demonstrated a shorter cannulation time at each attempt (p < 0.001). The novel sled improved the success rate and efficiency of ultrasound-guided phantom vessel cannulation.
-
Randomized Controlled Trial Comparative Study
Intra-operative rewarming with Hot Dog(®) resistive heating and forced-air heating: a trial of lower-body warming.
Resistive heating is an alternative to forced-air warming which is currently the most commonly used intra-operative warming system. We therefore tested the hypothesis that rewarming rates are similar with Hot Dog(®) (Augustine Biomedical) resistive and Bair Hugger(®) (Arizant) forced-air heating systems. We evaluated 28 patients having major maxillary tumour surgery. ⋯ Morphometric characteristics were comparable in both groups. Temperature increased at twice the rate in patients assigned to forced-air warming, with an estimated mean (SE) slope of 0.49 (0.03) °C.h(-1) vs 0.24 (0.02) °C.h(-1) (p < 0.001). Resistive heating warmed at half the rate of forced air.