Anaesthesia
-
Uncontrolled studies suggest that magnesium sulphate controls spasms in patients with established tetanus. We performed a meta-analysis of controlled trials that compared magnesium sulphate with placebo or diazepam for the treatment of patients with tetanus. We searched PubMed, Scopus, Embase and the Cochrane clinical trials registry. ⋯ Magnesium sulphate did not reduce mortality, relative risk (95% CI): vs placebo, 0.80 (0.41-1.58); vs diazepam, 1.11 (0.70-1.75). The data on duration of total intensive care unit stay, total hospital stay and the need for ventilatory support were conflicting and pooling of results could not be done due to methodological differences of individual trials. More controlled trials are needed to assess the effect of magnesium sulphate on reducing autonomic instability, spasms, duration of intensive care and hospital stays and the need for mechanical ventilation.
-
Review Meta Analysis Comparative Study
A meta-analysis of the accuracy and precision of the ultrasonic cardiac output monitor (USCOM).
The ultrasonic cardiac output monitor is a non-invasive, continuous-wave Doppler monitor that can be used to measure cardiac output. Its accuracy and precision in peri-operative and critical care has been assessed with varied results. ⋯ The mean weighted bias was -0.39 l.min(-1) (95% CI -0.25 to -0.53 l.min(-1) ), precision 1.27 l.min(-1) and percentage error 42.7% (95% CI 38.5-46.9%). The ultrasonic cardiac output monitor achieved similar agreement with bolus thermodilution to that of other minimally invasive methods of peri-operative cardiac output monitoring, and may have a useful role in cardiac output monitoring.
-
Review Meta Analysis
A meta-analysis of prevention of postoperative nausea and vomiting: randomised controlled trials by Fujii et al. compared with other authors.
The population sampling in randomised controlled trials by Fujii et al. have been shown to exhibit unusual distributions. This systematic review analysed the effectiveness of prophylactic antiemetics in trials by Fujii et al. compared with other authors. Granisetron was more effective in trials by Fujii et al., relative risk ratios (RRR (95% CI)): nausea 0.53 (0.42-0.67), p=0.00021; vomiting 0.60 (0.50-0.73), p=0.00094. ⋯ In contrast, in studies by Fujii et al., postoperative nausea and vomiting was more likely if granisetron was administered alone: nausea 4.20 (1.94-9.08), p=2.6×10(-4) ; vomiting 4.50 (2.55-7.97), p=2.3×10(-7); nausea or vomiting 5.00 (2.84-8.81), p=2.5×10(-8). Similarly, droperidol was less effective in studies by Fujii et al. if administered alone: vomiting 2.76 (1.25-6.11), p=0.01; nausea or vomiting 2.96 (1.46-6.00), p=2.7×10(-3). The conclusion is that if, as recommended, data with unusual distributions are removed from meta-analysis and articles by Fujii et al. excluded, then the antiemetic effects of granisetron and ramosetron are greatly reduced; further, there is no evidence of synergism between antiemetics and indeed, some evidence of antagonism between antiemetic agents.
-
Meta Analysis Guideline
Multidisciplinary guidelines for the management of tracheostomy and laryngectomy airway emergencies.
Adult tracheostomy and laryngectomy airway emergencies are uncommon, but do lead to significant morbidity and mortality. The National Tracheostomy Safety Project incorporates key stakeholder groups with multi-disciplinary expertise in airway management. , the Intensive Care Society, the Royal College of Anaesthetists, ENT UK, the British Association of Oral and Maxillofacial Surgeons, the College of Emergency Medicine, the Resuscitation Council (UK) the Royal College of Nursing, the Royal College of Speech and Language Therapists, the Association of Chartered Physiotherapists in Respiratory Care and the National Patient Safety Agency. ⋯ The final algorithms describe a universal approach to managing such emergencies and are designed to be followed by first responders. The project aims to improve the management of tracheostomy and laryngectomy critical incidents.
-
Review Meta Analysis
Use of plethysmographic variability index derived from the Massimo(®) pulse oximeter to predict fluid or preload responsiveness: a systematic review and meta-analysis.
This systematic review and meta-analysis assessed the accuracy of plethysmographic variability index derived from the Massimo(®) pulse oximeter to predict preload responsiveness in peri-operative and critically ill patients. A total of 10 studies were retrieved from the literature, involving 328 patients who met the selection criteria. ⋯ This could be explained by a lower accuracy of plethysmographic variability index in spontaneously breathing or paediatric patients and those studies that used pre-load challenges other than colloid fluid. The results indicate specific directions for future studies.